lead forensics image

Hygienic Centrifugal Pump

Hygienic Centrifugal Pump
Hygienic Centrifugal Pump

Hygienic Centrifugal Pump

ATEX icon FDA icon ISO icon CE icon EN10204 icon Tapflo 5 year guarantee icon

Tapflo UK’s CTH Hygienic Centrifugal Pump range delivers exceptional sanitary performance for the Food, Beverage and Pharmaceutical industries. Manufactured from AISI 316L Stainless Steel and electropolished to Ra<0.8, these pumps offer superior mechanical strength.

Able to withstand temperatures up to 180°C, the CTH Hygienic Centrifugal Pump is durable and offers superior corrosion resistance, making it the ideal pump for demanding applications.

Typical industries/applications for our Hygienic Centrifugal Pump:

  • Dairy
  • Beverage
  • Food
  • Pharmaceutical
  • Cosmetics
  • Breweries and wineries

Max. Flow:

Max. Head:

Max. Temp:

Material:

74m³/hr

100m

180°C

Metal

ATEX icon FDA icon ISO icon CE icon EN10204 icon Tapflo 5 year guarantee icon

Tapflo’s CTH Hygienic Centrifugal Pump range is suitable for various applications within the Food, Beverage and Pharmaceutical industries at competitive pricing and quick lead times. The Hygienic End Suction, Close Coupled, Single Stage Centrifugal Pumps feature either an Open (6 mm Solids Passage) or Semi-Open Impeller and are manufactured from Stainless steel AISI 316L, electro polished to Ra <0.8, to offer high mechanical and corrosion resistance for a plethora of hygienic applications at competitive pricing.

Long-Coupled Hygienic Centrifugal Pump

The CTH Pump is available with a long-coupled design. Typically the close-coupled design can handle fluids up to 90°C but with the long-coupled design, liquids with a higher temperature, up to 180°C can be pumped. We also recommend this design when handling highly flammable fluids or when the pump will be installed in a harsh ATEX zone. Installing a long-coupled design protects the motor if the mechanical seal fails, there is the possibility that if you were handling flammable liquids with a close-coupled pump, a leak could cause a spark and be extremely hazardous.

  • Pump casing & wetted parts electropolished to Ra<0.8
  • FDA & EC1935 approved mechanical seals and elastomers
  • Hygienic connections with DIN 11851 as standard
  • Viscosity: Max 200 cSt
  • Particles: max diameter of 6mm (with standard open impeller)
  • ATEX rating, ideal for hazardous zones
  • Auxiliary applications such as transfer of CIP liquids, detergents and water

The CTH Pump has been innovatively designed with only 19 components, enabling it to be maintained and troubleshot in a limited time frame. This results in very short downtimes and extremely low maintenance costs. In fact, in many cases, once installed, these pumps are maintenance-free! The modular design enables the pumps to be supplied with various build options, making it an incredibly robust and versatile pump suitable for a wide range of applications and installations.

Furthermore, with casing and impeller in <0.8 Ra electro-polished stainless steel AISI 316L, and possibilities for draining & also fitted with hygienic shroud & jacketing options means it meets the demands of cleanability and quality of high finish required within Food, Beverage and Pharmaceutical industries.

The CTH Pump is also available with a drain plug in various designs, including facing vertically down, vertically at an angle, facing sideways and horizontally facing forward. Speak to a member of the team to discuss including a drain plug on your final design.

The CTH Hygienic Centrifugal Pump Range is suitable for a wide variety of applications within the Food, Beverage and Pharmaceutical industries. As they can be ATEX rated they can also be used for hazardous zones. They are ideally suited for the transfer of various ingredients and products like:

  • Edible oil
  • Flavourings
  • Alcohol
  • Dairy products
  • Juice

When offered with a heating jacket, there are further possibilities like pumping margarine, paraffin and even chocolate.

There are also many auxiliary applications such as the transfer of CIP liquids, detergents and water. Typically used for tank-to-tank transfer applications, the CTH can also be used for pressure boosting, dispensing, loading and offloading, tank cleaning, batching and metering when used in conjunction with some of our wide range of control accessories.

Mechanical Seal Single ceramic/graphite (standard), SiC/SiC or SiC/graphite, Optional with Lubrication or Flushing
O-Rings EPDM FDA approved (standard), or FEP/silicone FDA approved
Motor IP55; IEC frame B34; Available with ATEX cat 2 or 3; Eex e or Eex d, IE3
Pressure Rating 100m (PN10)
Temperature Max 90°C; 180°C for long coupled pump
Viscosity Max ~200 cSt
Particles Max diameter is 6 mm (std open impeller); bigger if soft particles
Drive Type Electric
Flow Rate up to 74 m³/hr
Pressure up to 100m
Material Stainless Steel AISI 316L
Self-Priming No
Solids Handling 6mm
Viscosity 0-200 cSt
Connection points DIN 11851 thread (standard)
DIN 32676 clamp
ISO 2852 clamp
SMS thread
RJT thread

Hygienic Shroud: polished in AISI 304L, protects the motor from spraying water during the pump cleaning procedure.

Buffer Fluid System: an oil resevoir is connected to the mechanical seal chamber for applications that may solidify or crystalise.

Long Coupled: for pumping hot liquids, complete on a baseplace with coupling and cover.

Casing Drainage: draining plug with a variety of connection types allowing the pump to be emptied.

Adjustable feet: allows for easy cleaning underneath the pump and easy transport if the pump needs to be moved.

Heating Jacket:

To use a Tapflo Hygienic Centrifugal Pump with a Heating Jacket, a few extra parts are required, listed below.

  • 1 x Pump Back Cover for Heating Jacket (111)
  • 1 x Pump Back Casing with Heating Jacket (120)
  • 2 x Joint for Pump with Heating Jacket (125)

The jacket is welded into the pump back casing and a heating or cooling medium is continuously circulated in the jacket. Heating Jackets can be fitted in order to provide greater protection for the mechanical seal in cases where there is a risk of solidification of the product being pumped.

They can also be used when the temperature of the pumped product has to be maintained to a specific temperature, high or low. The jacket has two ISO G ½” connections, other options are available upon request, such as flanged. Connection to the jacket is done by using flexible hoses to prevent any undue stress and strain on the heating jacket connectors. The medium used needs to be fully compatible with the materials of the pump.

Electro-Polished, Stainless Steel AISI 316

Electro-Polished, Stainless Steel AISI 316L, Hygienic Shrouds can easily be fitted to provide added protection for the motor during wash-downs as well as an easier cleaning surface with increased resistance to bacterial build-up.

Additional Parts Required

1 x Hygienic Pump Shroud (31) 4 x Shroud Feet (34) 4 x Shroud Feet Screws (341) 4 x Shroud feet Screw Washers

Largest UK Stock

Same Day Quote

Fastest Delivery

Largest UK Stock

Same Day Quote

Fastest Delivery

Looking for more information about the services offered by Tapflo UK?

Our friendly team at Tapflo UK would be more than happy to assist you further with any pump solutions, delivery information or questions you have. If you need additional support on-site, you can speak to a member of the team today to organise a site visit.

Give us a call now:

02380 252 325

Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
knowledgebase
careers
catalogue
Filter by Categories
Blog
Case Studies